D12IR Infrared Gas Transmitter

ATI’s Series D12 Gas Transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact IR sensor in a corrosion resistant housing with sintered flame arrestor to meet hazardous area classification requirements, and is suitable for most plant environments. The D12-IR gas transmitter eliminates the poisoning problems inherent in catalytic bead sensors. While catalytic LEL sensors offer reliable service, the presence of silicon vapors, hydrogen sulfide, and halogenated hydrocarbons can quickly degrade sensor performance. Infrared sensing technology is not susceptible to these potential interferants, which means greater measurement stability and longer sensor life.

D12-IR transmitters can be factory calibrated for volumetric methane measurements in special applications. Ranges from 0-10% to 0-100% by volume are available. A separate sensor is also available for high percent level measurements of heavier hydrocarbons such a butane and propane.

The D12-IR transmitter can also be configured with Infrared sensor for carbon dioxide (CO2) or nitrous oxide (N2O) detection.  All sensor versions can operate in diffusion mode for ambient air or with a flow cell for pumped samples.
Because the IR sensor is always in an active state, the transmitter continuously monitors critical sensor functions and indicates any sensor problems, both on the display and via the analog output.

Transmitters are designed for operation in hazardous areas. The cast aluminum housing for the D12 transmitter is rated for Class 1, Division 1, Group B, C, D locations and is UL, FM, and CSA certified.

The transmitter is available with either HART™ or MODBUS™ protocol. The HART™ protocol supports the HART™ Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The MODBUS™ protocol supports 9600 baud access to concentration and status information, and supports alarm setup and many other functions on either RS485 or RS232 (software selectable).

Features:
• LCD Graphics Display: Gas concentrations are displayed in large, easy to read numbers. The display also provides alarm indication and complete menus for setting up operating parameters. A backlight is standard for good visibility in low light.
• Internal Data Logger: Measured gas values are stored at user definable intervals and can be recalled when needed on the LCD display. Data can be downloaded using the MODBUS ™ interface.
• Non-Intrusive Operation: Operating functions such as calibration, alarm setup, alarm reset, data view, and setup options are all available using a magnetic tool. It is not necessary to open the enclosure when making adjustments.
• Password Protection: Program settings stored in the transmitter may be protected by a user selectable 4-digit password. Operators may still review all functions, but changes may only be made by authorized personnel.
• Modular Electronics: The D12 electronic assembly plugs easily into the power supply board in the base of the enclosure. Transmitters can be removed for wiring and quickly replaced in the event of a fault condition.
• Explosion Proof Enclosure: Transmitters are designed for operation in hazardous areas. The cast aluminum housing for the D12 transmitter is rated for Class 1, Division 1, Group B, C, D locations and is UL, FM, and CSA certified.
• Scalable 4-20 mA: The output range for a particular sensor is programmable within the range boundaries set in that sensor.
• Explosion-proof Sensor Design: Infrared sensing element is protected by stainless steel housing and flame arrestor
• Fail-safe Sensor Operation: Because the IR sensor is always in an active state, the transmitter continuously monitors critical sensor functions and indicates any sensor problems, both on the display and via the analog output.
• High Range Methane Measurement: D12-IR transmitters can be factory calibrated for volumetric methane measurements in special applications. Ranges from 0-10% to 0-100% by volume are available. A separate sensor is also available for high  percent level measurements of heavier hydrocarbons such a butane and propane.
• Sensor Calibration History: Each time a sensor is zeroed or spanned, the data is stored in memory. Calibration history can be recalled and sensor condition reviewed by operating personnel when necessary.
• Three Internal Alarm Relays: Optional relay outputs can be used for local alarm functions. All relays are programmable for setpoint, hysteresis, on-delay, off-delay, and other variables. Even a remote reset feature is provided for in the transmitter design.
• Analog Output Simulation: Transmitter analog output can be set to user definable values. This provides for complete loop testing without the need to apply gas to the sensor.
• Relay Output Simulation: Alarm relays may be activated on command to allow testing of local alarm devices. Any combination of relays may be activated based on operator selection. Output and alarms may also be inhibited for maintenance and calibration.
• Serial Communication Interface: The transmitter is available with either HART™ or MODBUS™ protocol. The HART™  protocol supports the HART™ Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The MODBUS™ protocol supports 9600 baud access to concentration and status information, and supports alarm setup and many other functions on either RS485 or RS232 (software selectable). Comes with a register/tag database on a 3-1/2" diskette